138kv 132kv Power Transformer
LED LIGHTING GROUP

.webp)
Primary Voltage Ratings : 132kV, 138kV or others
Secondary Voltage Ratings : 11/10.5/6.6/6.3kV or others
H.V. Tap Range : ±8×1.25% or others
Connection Type : YNd11 or others
Type : oil immersed transformer
138 kV and 132 kV Transformer is based on Standard 1. GB 6451 Specification and technical requirements for oil-immersed power transformers;2. IEC 60076 Power Transformers;3. AS NZS 60076 Power Transformers;4.CSAC88-16 Power Transformers;5. ANSI/IEEE C57.12.00 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers;6. GOST R 52719 Power Transformers - General Specifications; 7. EN60076 Power Transformer;8. Local After-Sales Services In North America South America and other regions respond to your needs within 24 hours.
138 kV 132 kV Transformer Certificates
The design and manufacturing of SGJZ 138KV 132KV transformers fully meet GB 6451, IEC 60076, AS NZS 60076, CSAC88-16, ANSI/IEEE C57.12.00, GOST R 52719, EN60076 standards. SGJZ's professional engineering team project transformer design experience. According to your needs and technical requirements, provide you with the most suitable transformer solution.
138 kV and 132 kV Transformer is based on Standard 1. GB 6451 Specification and technical requirements for oil-immersed power transformers;2. IEC 60076 Power Transformers;3. AS NZS 60076 Power Transformers;4.CSAC88-16 Power Transformers;5. ANSI/IEEE C57.12.00 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers;6. GOST R 52719 Power Transformers - General Specifications; 7. EN60076 Power Transformer;8. Local After-Sales Services In North America South America and other regions respond to your needs within 24 hours.
Each 132 kV and 138kV transformer of SGJZ must be tested in strict accordance with the corresponding test standards before leaving the factory. After each test fully meets the corresponding requirements, it is sent to the customer to confirm a transformer test report. It can be packed and shipped.

|
132kv Class Three-phase two winding OLTC power transformer |
|||||
|
Rated Power |
High Voltage |
Low Voltage |
No-load Loss(kw) |
On-load Loss(kw) |
No Load current(%) |
|
10MVA |
132 kV |
6.3 kV |
11.8 |
51.2 |
0.82 |
|
12MVA |
138 kV |
6.6 kV |
13.7 |
59.5 |
0.82 |
|
15MVA |
|
10.5 kV |
16.3 |
73.1 |
0.76 |
|
20MVA |
11 kV |
19.5 |
88.4 |
0.76 |
|
|
25MVA |
|
22.7 |
105 |
0.69 |
|
|
30MVA |
27.4 |
126 |
0.69 |
||
|
37.5MVA |
32.9 |
148 |
0.63 |
||
|
50MVA |
38.9 |
184 |
0.63 |
||
|
60MVA |
46.4 |
221 |
0.57 |
||
|
110kv Class Three-phase two winding NLTC power transformer |
|||||
|
Rated Power |
High Voltage |
Low Voltage |
No-load Loss(kw) |
On-load Loss(kw) |
No Load current(%) |
|
10MVA |
132 kV |
6.3 kV |
11.8 |
51.2 |
0.64 |
|
12MVA |
138 kV |
6.6 kV |
12.4 |
59.5 |
0.64 |
|
15MVA |
|
10.5 kV |
15 |
73.1 |
0.59 |
|
20MVA |
11 kV |
17.8 |
88.4 |
0.59 |
|
|
25MVA |
|
21 |
105 |
0.54 |
|
|
30MVA |
25 |
126 |
0.54 |
||
|
37.5MVA |
29.9 |
148 |
0.56 |
||
|
50MVA |
35.3 |
178.5 |
0.52 |
||
|
60MVA |
41.9 |
221 |
0.48 |
||